Mixing desks:
Main House desk:
|
Yamaha M7CL-48
|
|
48x Mono 4x Stereo Inputs (Physical)
|
|
24x Outputs (Physical) configured as required
|
The M7CL is located in a permanent position in the Sound Control Room at the rear of the Circle and is not moveable.
The window of the Sound Control Room slides back for live sound mixing.
Moveable desk:
Yamaha 03D digital mixer. Dimensions (WxDxH) 460 x 516 x 204 mm
|
|
16x inputs (of which 8x mic inputs); 4x busses; 4x auxiliaries; stereo main output.
|
| The 03D is flightcased and can be moved. |
Playback, effects and processing equipment:
| 1 x Tascam MD-801R MKII minidisck recorder |
| 2 x Sony MDS E11 Minidisc recorder |
1 x Tascam DA30 DAT recorder
|
|
1x Denon DN-C635 CD player
|
|
1x Tascam 122 Mk.2 cassette deck
|
|
2x Yamaha Q2031 dual 1/3-octave graphic eq.
|
Installed Loudspeaker Systems:
|
4x d&b audiotechnic 902-LS (2 units each side, stalls level and circle level)
|
|
2x d&b audiotechnic 902-BX sub-bass units (1 each side)
|
|
2x d&b audiotechnic P1200L (permanently patched to FOH speaker system)
|
|
4x JBL Control 1 in stalls
|
|
2x C-Audio RA 501 (dedicated to delay speakers)
|
Portable effects/monitor loudspeaker & amplifiers:
|
4x Electro-Voice SX200
|
|
4x JBL Control 1
|
|
3x C-Audio ST600 (patchable as required to speaker points throughout stage and auditorium)
|
|
1x Yamaha P3200 (patchable as required to speaker points throughout stage and auditorium)
|
Tie lines:
There are plenty of mic and line level tie lines to all areas of the stage, orchestra pit, band room, auditorium and foyers.
SOUND (cont.) AND COMMUNICATIONS INFORMATION
Microphones:
|
4x Beyer M88 hypercardioid vocal mics
|
|
4x Beyer M201 hypercardioid instrument mics
|
|
2x AKG CK91/SE300 cardioid condenser mics
|
|
3x Audio Technica AT815b shotgun mics
|
|
2x Beyer MCE86 Hypercardioid short-shotgun mics
|
|
3x Crown PCC160 supercardioid boundary mics
|
|
3x Shure SM91 Unidirectional mics
|
|
4x EMO passive DI boxes
|
|
2x MTR passive DI boxes
|
|
4x MTR active DI boxes
|
|
2x BSS active DI boxes
|
|
5x adjustable boom stands
|
|
4x adjustable straight stands
|
|
4x short adjustable boom stands
|
|
2x banquet stand
|
Radio Microphones:
13 x Sennheiser EM 500 G2 receivers (UHF)
|
13 x Sennheiser SK 500 G2 transmitters and DPA 4060/4061 mics
|
| 2x Sennheiser EW300 receivers and hand held mics |
Our radio microphones are available for use, and a £75 per mic charge is levied.
The system uses either rechargeable AA batteries (in house), or alkaline batteries which must be provided by the visiting company.
The use of the radio mic must be pre-arranged with the Technical Manager prior to the Get-in.
Radio mic licencing:
We hold a site licence for the following frequencies:
|
854.900 MHz
|
858.650 MHz
|
|
855.275 MHz
|
860.400 MHz |
| 855.900 MHz |
860.900 MHz |
| 856.175 MHz |
861.200 MHz |
| 856.575 MHz |
861.550 MHz |
| 857.625 MHz |
861.750 MHz |
|
857.950 MHz
|
|
|
858.200 MHz
|
|
Also Additional frequencies 806.100 to 813.900 and 814.100 to 821.900
Miscellaneous:
3x 12-way microphone multicore boxes with 12m cable - connection points SL, SR and in the orchestra pit.
Mixing positions:
There is space in our sound control room or in prompt corner to site a small touring sound desk and associated equipment
There is also a mixing position at the rear of the stalls, the use of which entails the removal of 12 seats. A charge of £200 or the cost of lost seat sales (which ever is the greater) is made for the use of the rear-stalls position (waived in the case of musicals).
Communications:
Our ring intercom system is standard 3-pin TecPro equipment. Full show relay (audio and video) to all areas.
Prompt desk with calls, 14x Q-light circuits (patchable), intercom and video relay - situated SL.
Groups:
We have 6 dressing rooms and a band room. Three dressing rooms are large (up to 8 people) and three are small (2 to 3 people). The band room can be used as 2 dressing rooms if needs be (up to 8 people in each). All dressing rooms (except the band room) have showers and toilets; the band room has toilets only.
There is a wardrobe room with washing machine, tumble dryer, iron and ironing board.
There is also a visiting company office with outside phone line and fax machine.
Please note that we do not have any on site parking facilities. There is a pay car park for cars only just around the corner from the theatre, but we have no facilities for vans, minibuses etc to be parked near to the theatre.
For further details on any information contained in this specification, please contact :
Mark Passey (Technical Manager)
|
Tel: 01223 578905 |
| Julian Brooks (Chief Electrician) |
|
|
Tel: 01223 578948 |
Postal address:
Cambridge Arts Theatre, 6 St. Edwards Passage, Cambridge, CB2 3PJ
Email artstech@cambridgeartstheatre.com